| SPECIFICATION
- ASTM D-450A Type I
- Fed. Spec. #RP-381 Type I
PHYSICAL PROPERTIES
- Solids, Fed Spec. No. 791: 57% - 58%
- Spec. Gravity, Fed. Spec. SSR-406C, Method 209.2: 1.18
- ASH Fed. Spec. SSR-406C, Method 226: 5%
- Flash Point, Fed. Spec. SSR-406C, Method 217.01: 185ƒF
- Weight per Gal: 9.84 lbs.
- Touch Dry at 77°F: 24 hrs.
- Viscosity: 8000 cps
- Serv. Temp: 20° - 160°F
- Saturation: 35-C-540
- 1-6 Felts: 90%
- 7-8 Felts: 10%
- Low Temp Flex (6 hrs. at 25°F): Passes
APPLICATION Remove
all loose gravel, dirt and dust from roof by vacuuming, sweeping
or power broom. Repair all blisters, breaks or holes with Karnak
#170AF Tar Cement, Karnak #5540 Resat-Mat, or Karnak #31 Fiberglass
Membrane.
BRUSH APPLICATION:
Karnak #168AF Tar Roof Resaturant is easily applied with a wide,
fiber brush at the rate of 7 to 8 gallons per 100 sq. ft.. After
application of Karnak #168AF Tar Roof Resaturant is completed,
clean, dry gravel should be reapplied at the rate of 400 lbs.
per 100 sq. ft.
SPRAY APPLICATION:
Efficiently sprayed on large areas with standard mastic pump-type
equipment. Apply at the rate of 7 to 8 gallons per 100 sq. ft..
After application of Karnak #168AF. Tar Roof Resaturant is completed,
gravel should be re-applied at the rate of 400 lbs. per 100 sq.
ft.
COVERAGE Apply
at the rate of 7 to 8 gallons per 100 sq. ft.
CARE OF TOOLS Tools
and other equipment should be thoroughly cleaned with coal tar solvents,
taking necessary precautions when handling combustible materials.
CAUTION Do
not use near open flame. Avoid breathing solvent fumes and prolonged
contact with skin. Do not take internally. If swallowed, do not
induce vomiting. Call a physician immediately. Keep out of reach
of children. Keep container covered when not in use. Do not thin.
Dispose of in an environmentally safe manner.
PACKAGING Available
in 5 gallon pails and 55 gallon drums. |