| ADVANTAGES The
asphaltic oils in the base coating are protected from the intense
rays of the sun by the reflective properties of the aluminum. Most of the sun's rays are reflected by this aluminum shield, thereby
preventing these oils from being "cooked" out of the base
coating. The coating, therefore, retains its resilient characteristics
and will not prematurely crack or dry out. During the hot summer
months, Karnak #169 Non-Fibered Aluminum Roof Coating will help
reduce indoor building temperatures and improve inside living and
working conditions. Karnak #169 Non-Fibered Aluminum Roof Coating
prevents the sun's rays from penetrating the roof coating and passing
the heat into the building interior.
USES Karnak
#169 Non-Fibered Aluminum Roof Coating is ideal for use on *modified
bitumen membranes, metal corrugated roofs and steep asphalt surfaces.
New asphalt roof surfaces should weather a minimum of 90 days before
being coated with Karnak #169 Non-Fibered Aluminum Roof Coating.
However, it can be coated on roofs 5-7 days after Karnak asphalt emulsions
have been applied.
SPECIFICATION
- ASTM D-2824 Type I
- ASTM D-3805
- UL Class A (See UL Directory)
SURFACE PREPARATION All
surfaces should be clean, dry and free from oil, grease, dust, dirt,
loose paint or other foreign matter. Badly weathered or alligatored asphalt surfaces should be primed with Karnak 100AF Non-Fibered Aluminum Roof Coating or 220AF Fibered Emulsion prior to coating with 169AF Non-Fibered Aluminum Roof Coating. Allow emulsion primer to cure a minimum of 5-7 days before application of aluminum coating.
APPLICATION Karnak
#169 Non-Fibered Aluminum Roof Coating should be spread uniformly
over the roof surface. Care should be taken not to overwork the
coating while applying. This will have a damaging effect on the
leafing action of the aluminum. Be sure to mechanically mix the
aluminum coating thoroughly before using. Karnak #169 Non-Fibered
Aluminum Roof Coating can be applied with a soft roof brush, roller
or spray.
COVERAGE Apply
at the rate of 0.5 to 1 gallon per 100 square feet.
CARE OF TOOLS Tools
and other equipment should be thoroughly cleaned with mineral spirits,
taking necessary precautions when handling combustible materials.
CAUTION Do
not use near open flame. Avoid breathing solvent fumes and prolonged
contact with skin. Do not take internally. If swallowed, do not
induce vomiting. Call a physician immediately. Keep out of reach
of children. Keep container covered when not in use. Do not thin.
Dispose of in an environmentally safe manner. Cover air intakes during application and while drying.
PACKAGING Available
in 5 gallon pails and 55 gallon drums.
Note: When coating Modified Bitumen Membranes
with Aluminum Coatings, Karnak recommends coating modified bitumen
membranes as soon as possible after the membrane is installed. Karnak's
experience, laboratory and field tests, as well as NRCA, RCMA and
ARMA reports, indicate that aluminum coating will reduce the combined
effects of ultraviolet rays, heat and moisture, which, especially
on APP modified bitumens, enhance exudation that can cause discoloring
and delamination of any surface coating Karnak's experience, laboratory
and field tests, as well as NRCA, RCMA and ARMA reports, indicate
that aluminum coating will reduce the combined effects of ultraviolet
rays, heat and moisture, which, especially on APP modified bitumens,
enhance exudation that can cause discoloring and delamination of
any surface coating
COLD-PROCESS SYSTEMS AND COATINGS, EITHER EMULSION
OR SOLVENT BASED, SHOULD ONLY BE INSTALLED ON DECKS WITH POSITIVE
DRAINAGE.
PER NRCA, (NATIONAL ROOFING CONTRACTORS
ASSOCIATION) "THE CRITERIA FOR JUDGING PROPER SLOPE FOR DRAINAGE
IS THAT THERE BE NO EVIDENCE OF STANDING WATER ON THE DECK 48 HOURS
AFTER IT STOPS RAINING."
|