| SPECIFICATION
- ASTM D-3019 Type III
- ASTM D-4479 Type I
SURFACE PREPARATION All
surfaces to be coated should be dry and free of all dust, dirt or
other loose debris.
BRUSH APPLICATION:
Under normal conditions, Karnak #78AF Cold Process Cement should
be applied by brush at the rate of 2 gallons per 100 sq. ft.
SPRAY APPLICATION:
On large roof areas Karnak #78AF Cold Process Cement can be sprayed
using airless spray equipment. Application should be made at the
rate of 2 to 2 1/2 gallons per 100 sq. ft.
CAUTION Do
not use near open flame. Avoid breathing solvent fumes and prolonged
contact with skin. Do not take internally. If swallowed, do not
induce vomiting. Call a physician immediately. Keep out of reach
of children. Keep container covered when not in use. Do not thin.
Dispose of in an environmentally safe manner.
PACKAGING Available
in 5 gallon pails and 55 gallon drums. |